STANDARD FEATURES & INCLUSIONS – Foodservice GN Freezer Walliglu
Extended Warranty Term – 5 year Parts on construction against manufacturing defects or faults and 2 years Labour.
HACCP Certified – acoustic and visual HACCP alarm automatically activated when temperatures exceed HACCP defined critical temperature and time limits, 255 events recorded and stored within the controller software with detailed reports on last 16 alarms to include; Alarm Duration, Alarm Time (period of time), Temperatures and Cause.
+43ºC Ambient (T Class) – all cooling and mechanical components are engineered to perform reliably in a tropicalized climate of +43ºC ambient.
Certifications & Marks of Conformity - HACCP Certified, 2006/42/CE, NF, EN 60335-1, EN 60335-2-89, EN 55014-1, EN55014-2, EN 61000-3-2, EN 61000-3-3, 2004/108/CE, RoHS, RAEE, WEEE, REACH.
Intelligent Defrost Systems (IDS) – demand responsive, reliable and highly-efficient ‘hot-gas’ defrost eliminating the need for extra energy input will only initiate when necessary & only when necessary without consideration of previous defrost cycles and without the need for predetermined time-based defrost intervals.
Extreme-High-Performance – 50mm high-density (45kg/m3) rigid foam polyurethane insulation, Zero Ozone Depleting – (100% CFC-HCFC Free).
AISI304 Construction – entirely constructed of AISI304 high-grade-food-safe stainless steel externally and internally featuring a mirror polished interior with a coved ceiling and floor base and radius corners (R=12) both top and bottom. Easy ‘tool free’ removable shelving system for cleaning is in AISI304 stainless.
Adaptive Precision Controller – adaptive and remarkably flexible IP65 Water & Dust Ingress Protected ‘Intelligent’ controller with (LCD) Liquid Crystal Display for clear text monitoring of temperatures, functions, cycles, alarms, compressor running, defrost cycle, dripping indicator, temperature & humidity level indicator, cooling, door open alarm, and clean condenser. Built-in features include; audible and visual multi-function alarm alert system, fan speed management system, auto self-diagnostics system, and Intelligent Defrost System.
High-efficiency Refrigeration Systems – left-side mounted side mounted high-performance electronic controlled integral refrigeration system, entirely front ventilating refrigeration and electrics, condenser & evaporator/s with high exchange surface area for maximum output of refrigeration cycles, entire refrigeration system mounted on ‘slide-out’ guides to facilitate ease of maintenance and service.
High Exchange Evaporators & 'IQ' Cooling Fans – protected by food safe coating and AISI304 stainless steel shroud are positioned within the dead space rear of the door mullion/s for highly efficient cooling and perfect homogeneity.
Entirely Front Breathing – entirely front ventilating system to allow for installation hard-up against the rear, left side technical compartment side walls and ceiling.
Solid Panel Doors – AISI304 insulated stainless panel door with radius handle, self-closing at less than 90° with ‘stop’ (remains open unassisted) at 95° and to be fitted with replaceable magnetic balloon type door seals for a highly effective door closure and seal, and guarantee increased thermal efficiency.
Internal Lighting – LED interior light.
Auto self-diagnostics – is self-adjusting to ambient and operational conditions, continually accesses the performance of the refrigeration system and efficiency.
Waste Vaporizer – hot-gas disposal device to eliminate the defrosting water (drainage not required).
Over-current / Thermal Fuse Protection – inbuilt thermal protection in the event of a thermal compromise to prevent, and limit damage to equipment’s electrical components and reduce the risk of harm to the operator caused by overloads, or electrical safety breaches in unusual circumstances.
Service & Maintenance – facilitated via electronic controller to report a precise log of operating temperatures, cycles & alarm event history available in real time to service technicians, self-diagnostic test can be launched to ensure parameters are correct set to guarantee optimum operating capacity upon servicing/maintenance.